7 Tips for Choosing Formwork Magnets
ACI 347R-14 makes pour rate and concrete temperature key inputs when estimating lateral form pressure. Faster placement can leave less time for concrete to stiffen, increasing pressure on wall forms.
For normal-weight concrete, a useful upper-bound check is hydrostatic pressure: roughly 150 pounds per cubic foot, or about 150 pounds per square foot for each foot of concrete depth. That is substantial. A four-foot rise can mean about 600 psf near the base if full liquid pressure applies. ACI’s calculation methods also account for factors such as slump, vibration, and concrete mixture.
Use the project’s expected pour rate, temperature, lift height, and placement method to establish design pressure before selecting magnets. ACI 347R-14 provides guidance for estimating pressure; it does not set one universal magnet capacity. Compare the calculated demand with the form system’s documented capacity, including the load path through the panel, rails, and magnet contact surface.
Keep the steel clean and flat. A thin layer of concrete paste can reduce contact and make a strong magnet less dependable.
Check the supplier’s rated holding force and installation conditions, then have the responsible engineer verify the complete assembly. Do not treat a magnet’s advertised pull rating as the allowable form pressure. Field conditions vary. I would also recheck the pour plan when a cold morning, a high-slump mix, or a faster pump schedule changes the assumptions. Those details are easy to miss, and the calculation may need revision.