| Hazardous Area | Gas or dust classification | Identify whether the motor will operate in an explosive gas, vapor, mist, or combustible-dust atmosphere. | Gas zones 1 or 2; dust zones 21 or 22; or North American Class I, II, or III locations. | IEC 60079-10-1 for gas; IEC 60079-10-2 for dust; NFPA 70 for Class and Division systems. | Area classification drawing, hazardous-area study, and end-user installation requirements. | Required |
| Explosion Protection | Protection concept | Select a protection method that matches the classified area and motor construction. | Ex db flameproof enclosure; Ex eb increased safety; Ex ec equipment protection level for less hazardous areas; or dust protection by enclosure. | IEC 60079-0 and applicable protection-type requirements in the IEC 60079 series. | Certificate of conformity, certificate schedule, and complete marking information. | Required |
| Equipment Group | Gas or dust group | Choose equipment suitable for the specific substance group because ignition sensitivity and enclosure requirements differ. | Gas groups IIA, IIB, or IIC; dust groups IIIA, IIIB, or IIIC. | IEC 60079-0 equipment-group classifications. | Hazardous-substance data sheet and motor certificate showing the approved group. | Required |
| Temperature | Temperature class and maximum surface temperature | The motor surface temperature must remain below the ignition temperature of the surrounding hazardous material. | Gas: T1 to T6; dust: maximum surface temperature in °C, including the specified dust layer condition. | IEC 60079-0 and IEC 60079-7 or IEC 60079-1, depending on protection concept. | Temperature-class marking, thermal test data, and ambient-temperature limits. | Required |
| Certification Market | Regional approval route | Confirm the approval system accepted in the destination country before placing the purchase order. | IECEx certification; ATEX certification for the European Union; or local certification for other jurisdictions. | IECEx system; ATEX Directive 2014/34/EU; applicable national regulations. | Valid certificate, certificate number, marking photograph, and certification scope. | Required |
| North America | Class, Division, or Zone approval | For North American projects, verify that the marking matches the site classification method. | Class I, Division 1 or 2; Class II; Class III; or Zone 1/2 and Zone 21/22 configurations. | NFPA 70, UL 1203, CSA hazardous-location requirements, and approved certification scheme. | Listing or certification record, installation instructions, and hazardous-location marking. | Conditional |
| Electrical Rating | Rated power, voltage, frequency, and speed | Match the motor to the available power supply and driven-equipment duty. | Typical industrial ranges: 0.12–315 kW; 230/400 V or 400/690 V; 50 or 60 Hz; 2-, 4-, 6-, or 8-pole designs. | IEC 60034-1 for rotating-machine ratings and performance. | Technical data sheet, nameplate drawing, winding connection diagram, and test report. | Required |
| Efficiency | Energy-efficiency class | Specify an efficiency level that meets local energy-efficiency rules and total-cost objectives. | IE3 is commonly specified for general industrial motors; IE4 may be selected where regulations and design permit. | IEC 60034-30-1 and the energy-efficiency requirements applicable in the destination market. | Efficiency test report, loss data, and declared efficiency class at rated load. | Recommended |
| Ingress Protection | Enclosure protection rating | Select protection against dust, water, washdown, and outdoor exposure based on the installation environment. | IP55 for many indoor industrial installations; IP56, IP65, or IP66 where greater water or dust protection is required. | IEC 60034-5 and IEC 60529. | IP test report, enclosure drawing, cable-entry details, and drain-plug information. | Required |
| Ambient Conditions | Ambient temperature, altitude, and humidity | Confirm the motor’s thermal capability under actual site conditions rather than relying only on standard ratings. | Common reference ambient: −20 to +40 °C; altitude normally up to 1,000 m unless derating is calculated. | IEC 60079-0 and IEC 60034-1; project-specific environmental requirements. | Derating curve, allowable ambient range, altitude correction, and humidity limitations. | Required |
| Variable-Speed Operation | Variable-frequency drive compatibility | Verify that the motor certificate and thermal design permit operation with the proposed inverter or drive. | Approved speed range, minimum cooling speed, inverter-duty insulation, shaft-voltage mitigation, and permitted switching frequency. | IEC 60079-14 for electrical installations in explosive atmospheres; IEC 60034-17 and IEC 60034-25 for converter-fed motors. | VFD compatibility statement, speed-torque curve, thermal protection requirements, and certificate limitations. | Conditional |
| Thermal Protection | Winding and bearing temperature monitoring | Use thermal sensors where overload, restricted cooling, high ambient temperature, or variable-speed operation may occur. | PTC thermistors, RTDs, embedded thermal switches, or approved bearing sensors. | IEC 60079 installation requirements and the motor certificate conditions of use. | Sensor type, resistance data, terminal arrangement, trip settings, and control-circuit diagram. | Recommended |
| Mechanical Design | Mounting, frame, shaft, and bearings | Ensure interchangeability with the driven machine and compatibility with the required coupling or belt arrangement. | IEC frame sizes; B3 foot mount; B5 flange mount; B35 combined mount; keyed shaft; standard or insulated bearings as required. | IEC 60072 for dimensions and IEC 60034 series for rotating-machine requirements. | Outline drawing, shaft-load limits, bearing schedule, mounting dimensions, and balancing grade. | Required |
| Materials and Environment | Corrosion and weather resistance | Match paint system, fasteners, seals, and enclosure materials to chemical exposure and outdoor conditions. | Epoxy or marine-grade coating; stainless-steel fasteners; sealed terminal box; tropicalization where required. | Project coating specification, ISO 12944 where corrosion category is specified, and certificate limitations. | Coating system, dry-film thickness, material certificates, and corrosion-resistance test information. | Conditional |
| Cable Entry | Cable glands and blanking elements | Cable-entry components must maintain the motor’s hazardous-area protection and enclosure rating. | Certified glands matching cable diameter, thread type, armor, gas group, dust group, and IP requirement. | IEC 60079-1, IEC 60079-7, IEC 60079-14, and applicable gland certification requirements. | Gland certificates, thread specification, installation torque, sealing instructions, and spare-entry details. | Required |
| Noise and Vibration | Acoustic and vibration limits | Define acceptable noise and vibration levels to protect reliability and meet plant requirements. | Vibration acceptance based on machine size and operating speed; noise target commonly specified in dB(A) at rated load. | ISO 20816 for machine vibration evaluation; IEC 60034-9 for acoustic noise. | Routine vibration report, noise test method, balancing record, and acceptance criteria. | Recommended |
| Quality Control | Routine and type testing | Define inspection points before production to reduce certification, dimensional, and performance risks. | Insulation resistance, high-voltage withstand, no-load current, vibration, temperature rise, efficiency, and dimensional inspection. | IEC 60034-1 and relevant explosion-protection certification requirements. | Inspection and test plan, routine test certificates, calibration records, and nonconformance procedure. | Required |
| Supply Chain | Lead time, spare parts, and lifecycle support | Evaluate the complete supply risk, not only the unit purchase price. | Agreed production lead time; critical spare bearings, fans, terminal components, and seals; documented change-control process. | Project procurement specification and quality-management requirements. | Manufacturing schedule, spare-parts list, warranty terms, service network coverage, and end-of-life notification policy. | Recommended |
| Import and Compliance | Customs, labeling, and technical file | Prepare documents required for import clearance, site approval, and local inspection. | Commercial invoice, packing list, country-of-origin information, product marking, manuals, declarations, and certificates. | Destination-country customs rules, ATEX documentation requirements where applicable, and local electrical regulations. | Complete document pack in the required language, including nameplate artwork and installation instructions. | Required |