| DC Solenoid | Linear actuation, locking, latching, and small mechanical mechanisms | 12 VDC or 24 VDC | Approximately 0.2–3 A coil current; force commonly 5–150 N | Intermittent operation, commonly 5–25% ED; continuous-duty versions are available | IP40–IP65 | Check stroke, required force, response time, coil heating, return spring force, and whether operation is push or pull. |
| AC Solenoid Valve | Controlling compressed air, water, oil, or other compatible fluids | 24 VAC, 110–120 VAC, or 220–240 VAC | Typically 3–15 VA apparent power, depending on valve size | Often 100% ED when correctly sized and cooled | IP65–IP67 for protected industrial versions | Select by media compatibility, pressure range, port size, flow coefficient, ambient temperature, and fail-safe position. |
| Electromagnetic Relay | Low-power control of lighting, motors, heaters, and auxiliary circuits | 5, 12, or 24 VDC coil; contact circuits may be rated up to 250 VAC | Coil current commonly 20–150 mA; contacts commonly 5–16 A resistive | Continuous coil operation is common; switching duty depends on load and cycle frequency | Usually IP20 when mounted inside an enclosure | Verify contact voltage, resistive versus inductive load, inrush current, electrical life, isolation, and contact arrangement. |
| Electromagnetic Contactor | Frequent switching and isolation of motors, compressors, pumps, and heating equipment | 24 VDC, 24 VAC, 110–120 VAC, or 220–240 VAC coil | Typically 9–95 A AC-3 motor rating; coil current varies by frame size | Designed for repeated switching; typical utilization categories include AC-1 and AC-3 | IP20–IP55, usually installed inside a protected cabinet | Use motor starting current, horsepower or kW, utilization category, switching frequency, auxiliary contacts, and short-circuit coordination. |
| Electromagnetic Brake | Holding or stopping rotating shafts in motors, hoists, conveyors, and machine tools | 24 VDC, 90 VDC, or 180 VDC are common coil options | Approximately 0.3–5 A coil current; braking torque commonly 2–400 N·m | Holding brakes may use 100% ED; dynamic braking requires thermal and cycle analysis | IP44–IP65 depending on enclosure and mounting environment | Calculate static and dynamic torque, stopping energy, shaft speed, response time, wear, fail-safe behavior, and release voltage. |
| Electromagnetic Holding Magnet | Holding steel components, access doors, fixtures, guards, and material-handling equipment | 12 VDC or 24 VDC | Approximately 0.2–2 A; holding force commonly 50–1,500 N on clean flat steel | Continuous duty is common, provided coil temperature remains within limits | IP40–IP67 | Account for air gaps, surface finish, load direction, vibration, safety factor, residual magnetism, and power-loss release requirements. |
| Proportional Solenoid | Variable positioning or pressure and flow control in hydraulic and pneumatic systems | 12 VDC or 24 VDC | Approximately 0.5–3 A nominal coil current; force commonly 10–200 N | Continuous or high-duty operation with current-controlled drive electronics | IP54–IP67 | Match the current-control method, force-stroke curve, hysteresis, response time, feedback needs, and thermal limits. |
| Electromagnetic Clutch | Engaging and disengaging power transmission in conveyors, packaging machines, and automation systems | 12 VDC or 24 VDC | Approximately 0.5–4 A coil current; torque commonly 1–250 N·m | Intermittent or continuous operation depending on slip, speed, and heat dissipation | IP40–IP65 | Evaluate transmitted torque, engagement speed, allowable slip, cycle rate, shaft alignment, heat generation, and wear. |