| 1 | Substrate Material | Common options include galvanized steel, galvalume-coated steel, aluminum, and stainless steel. Galvanized and galvalume products require different corrosion-performance assessments. | Confirm the base-metal grade, coating type, nominal thickness, dimensional tolerances, and suitability for the project environment. | Mill test certificate, applicable material standard, thickness report, and independent verification when required. |
| 2 | Sheet Thickness and Profile | Metal cladding sheets are commonly specified by nominal thickness and profile geometry. Actual performance depends on span, rib height, support spacing, and wind loading. | Check whether quoted thickness is base-metal thickness or total coated thickness, and confirm effective cover width and panel depth. | Product drawings, tolerance data, load-span tables, and a project-specific structural calculation. |
| 3 | Metallic Coating Mass | Typical galvanized coating designations include Z275, while common aluminum-zinc coating designations include AZ150. The number generally refers to total coating mass on both sides in g/m². | Confirm the coating designation, test method, minimum local value, and whether the quoted figure applies to both sides. | Coating-mass test report, production specification, and compliance statement against the requested standard. |
| 4 | Paint System and Film Thickness | Common exterior systems include polyester, silicone-modified polyester, and PVDF. Typical nominal topcoat thicknesses vary by system and supplier; PVDF systems are often specified at approximately 25 μm. | Review resin type, primer and back-coat construction, total dry-film thickness, color-retention requirements, and warranty exclusions. | Coating technical data sheet, dry-film measurement records, accelerated-weathering results, and written warranty terms. |
| 5 | Corrosion Resistance | Performance depends on atmospheric exposure, salt concentration, humidity, cut edges, fasteners, drainage, and contact with incompatible metals. Coastal and industrial sites generally require more stringent protection. | Assess the site exposure category and verify that the substrate, coating, accessories, and installation details are compatible. | Corrosion-test data, exposure classification, edge-treatment details, and installation recommendations. |
| 6 | Fire Performance | Fire classification is affected by the complete wall or roof assembly, including insulation, membranes, cavities, joints, and fixings. A metal sheet alone does not establish the fire rating of the finished system. | Confirm the required national or project-specific classification and ensure the tested assembly matches the proposed construction. | Fire-test or classification report under the required standard, with assembly details and field-of-application limits. |
| 7 | Dimensional Accuracy | Width, length, squareness, flatness, camber, and profile tolerances influence installation speed, joint alignment, and water-tightness. | Determine inspection frequency and acceptance tolerances, particularly for long panels, concealed-fix systems, and visible façades. | Inspection and test plan, sample measurements, approved shop drawings, and pre-shipment inspection records. |
| 8 | Manufacturing and Quality Control | Reliable production control should cover incoming steel, roll forming, coating appearance, profile dimensions, cutting, labeling, and packaging. | Check whether quality inspections are documented for every batch and whether nonconforming products are traceable. | Quality manual, batch traceability procedure, inspection records, calibration certificates, and factory audit results. |
| 9 | Packaging and Export Logistics | Long and thin panels can be damaged by poor stacking, moisture retention, abrasion, forklift handling, and inadequate container loading. | Confirm seaworthy packaging, maximum bundle weight, loading method, moisture protection, labeling, and replacement procedures for transit damage. | Packing specification, loading photographs, shipping marks, commercial documents, and agreed damage-claim process. |
| 10 | Technical Support and Total Cost | The lowest unit price may not provide the lowest installed cost. Engineering support, accessories, waste, lead time, maintenance, and warranty conditions affect total project value. | Compare equivalent specifications, tooling charges, minimum order quantity, production lead time, spare quantities, and after-sales response. | Itemized quotation, technical submittal, installation guidance, sample approval, lead-time commitment, and written after-sales terms. |